Data Core Infotech Logo
Data CoreInfotech
DEPLOYMENT|ITMS-MOD-CAT
INTELLIGENT TRANSPORTATION SYSTEMS (ITS/ITMS)

AI-ITMS Capability Matrix

Procurement-grade software and edge-hardware modules designed for Indian municipal corporations, traffic police commands, and smart city SPVs. Each module adheres to strict verification classifications.

DEPLOYED MODULES: 02 (SIGNAL CONTROL & ANALYTICS)|BENCH EVALUATED: 01 (ENFORCEMENT)|CONCEPTUAL: 01 (EMERGENCY PREEMPTION)
MOD-ASC-01
DEPLOYMENT|DCI-VFY-ASC-DEP01
AUTONOMOUS ACTUATION

Adaptive Signal Control (ASC)

Fully autonomous, cycle-by-cycle adaptive traffic signal actuation executing on-box at the intersection. Replaces rigid fixed-timer schedules with dynamic queue-responsive phase duration.

PROCUREMENT IMPACT: Reduces intersection idling and stops without requiring expensive centralized traffic computers or recurring cloud server licensing fees.
CORE TECHNICAL CAPABILITIES
Dynamic Green Extension & TruncationField-verified in Udaipur and Jaipur pilots

Senses vehicle headway gaps in real time. If vehicle clearance drops below 2.8 seconds, green time is instantaneously terminated to service pending cross-corridor queues.

Multi-Ring Phasing & Slipway Control3-phase & 4-phase intersection geometries

Compliant with Indian Road Congress (IRC:SP:87) phase structures, managing complex rotary slipways, concurrent pedestrian calls, and protected right turns.

Hardwired Interlock Safety BarrierZero unsafe actuations over 39+ continuous days

AI outputs pass through an analog conflict monitor preventing any contradictory green states at the physical copper relay level.

EDGE HARDWARE SPECIFICATION
DCI Edge Compute Node (32 TOPS NPU)4x - 6x IP RTSP Optical SensorsGalvanically Isolated 12-Channel Pilot Relay BoardSurge Protective Device (SPD) Class II
STANDARDS: IRC:SP:87-2019 • MoRTH ITMS Spec • IS/IEC 60947Production Ready / Pilot Deployed (Fatehpura & Rambagh)
MOD-ANL-02
DEPLOYMENT|DCI-VFY-ANL-DEP02
SPATIAL TELEMETRY

Traffic Analytics & Flow Dynamics

High-precision multi-class vehicle classification, spatial density heatmaps, and Passenger Car Unit (PCU) volume counting computed on edge with sub-15ms latency.

PROCUREMENT IMPACT: Provides municipal corporations and traffic police with audit-grade traffic volume data for junction redesign, flyover feasibility, and DPR formulation.
CORE TECHNICAL CAPABILITIES
Heterogeneous Vehicle Classification97.4% optical classification confidence

Identifies 8 vehicle classes (2W motorcycles/scooters, 3W auto-rickshaws, e-rickshaws, cars, light commercial, buses, heavy trucks, tractors) simultaneously in dense mixed traffic.

Queue Length & Density Vectoring± 0.5m distance accuracy up to 120m corridor

Measures physical queue length in meters and spatial density percentages rather than simple vehicle counts, accommodating bumper-to-bumper Indian driving behavior.

Origin-Destination (OD) Flow InferenceReal-time PCU/hour calculation per approach

Calculates turning movement percentages (left, through, right, U-turn) without requiring automated number plate recognition (ANPR) tracking.

EDGE HARDWARE SPECIFICATION
DCI Edge Compute Node or ICCC Server Ingestion4MP High-Definition Optics with 120dB WDRLocal Encrypted NVMe Storage (1TB)
STANDARDS: MoHUA Smart Cities Reference • IRC:SP:87Production Ready / Pilot Deployed
MOD-ENF-03
DEMONSTRATION|DCI-VFY-ENF-DEM01
SAFETY & COMPLIANCE

Enforcement & Incident Intelligence

Automated optical incident detection identifying red-light jump violations, wrong-way movements, stationary junction blockages, and stalled vehicle events.

PROCUREMENT IMPACT: Empowers traffic police control rooms with instant incident triage, reducing secondary congestion and accelerating emergency tow-away dispatch.
CORE TECHNICAL CAPABILITIES
Stop-Line Violation Spatial TriggeringZero false triggers during amber clearance phase

Synchronizes directly with signal head controller state. Detects vehicles crossing the stop bar strictly during red phase with bounding polygon confirmation.

Wrong-Way Movement & Stationary Stall Alerts< 2.0s incident alert generation

Tracks directional velocity vectors. Immediately triggers optical telemetry alert when vehicle proceeds opposite to gazetted traffic direction or halts in yellow box.

Junction Gridlock Spillback DetectionAlgorithmic spillback prevention loop

Identifies when downstream intersections fail to clear, preventing upstream signals from flushing more vehicles into a blocked intersection.

EDGE HARDWARE SPECIFICATION
DCI High-Speed Vision Sensor ArrayEdge Hardware Cryptographic Security Module (TPM 2.0)Gigabit Switch with 802.1Q VLAN Isolation
STANDARDS: CCTNS Schema Compliance • Section 136A MV Act 2019Demonstration Benchmark / Pilot Evaluated
MOD-PRE-04
CONCEPTUAL|DCI-VFY-PRE-CON01
CORRIDOR CLEARANCE

Transit Priority & Emergency Preemption

Green corridor clearance for ambulances, fire engines, and rapid transit buses via encrypted RF beacons or Computer-Aided Dispatch (CAD) GPS handshakes.

PROCUREMENT IMPACT: Guarantees rapid unimpeded emergency medical transport through high-density urban corridors without requiring manual police escort deployment.
CORE TECHNICAL CAPABILITIES
Automated Dynamic Green Corridor< 1.5s preemption actuation latency

Calculates approaching emergency vehicle arrival time (ETA) and sequentially initiates phase transitions to grant green right-of-way 15 seconds prior to arrival.

Rapid Post-Preemption RecoveryUnder 2 cycles to equilibrium restoration

Once emergency vehicle clears the junction, system executes an engineered recovery cycle to quickly clear accumulated cross-traffic queues without shockwaves.

Dedicated BRTS Transit Signal PriorityTargeted 15-20% bus travel time improvement

Grants slight green extensions or early green starts to public transit buses, maximizing passenger throughput along dedicated transit corridors.

EDGE HARDWARE SPECIFICATION
Emergency Vehicle On-Board Transponder / CAD GatewayDCI Edge Preemption Receiver ModuleAuxiliary Priority Dry Contact Inputs
STANDARDS: IRC Guidelines on Emergency Corridors • NTCIP 1211 Priority StandardsConceptual Architecture / Bench Validated
DEMONSTRATION|CALC-ITMS-FEAS
MUNICIPAL CORRIDOR FEASIBILITY MODEL

Empirical Impact & Carbon ROI Estimator

Calibrated against audited data from the 39-day Rambagh Circle deployment (4.88M vehicles, 65 KG daily CO₂ mitigation per junction). Adjust parameters to model your city's corridor.

CALIBRATION: RAMBAGH PILOT 2026 BENCHMARK
CORRIDOR PARAMETERSADJUST SLIDERS
12 Junctions
1 Pilot Node30 Arterial Trunk60 Zone-Wide
65,000 PCU
15,000 (Suburban)65,000 (Rambagh Baseline)120,000 (Major Metro Hub)
60s / vehicle
30s (Moderate)60s (Standard Pre-timed)120s (Severe Bottleneck)
Adaptive Advantage: DCI Dynamic Gap-Acceptance removes wasted green seconds and truncates phases when vehicle headway exceeds 2.8s, yielding an estimated -23s average delay reduction per vehicle approach.
ANNUAL CARBON MITIGATION
285 MT

Metric tonnes of CO₂ emissions eliminated annually by removing idle stop-and-go queuing.

BENCHMARK: 65 KG/DAY PER ARTERIAL JUNCTION
ANNUAL COMMUTER HOURS SAVED
1.82M Hrs

Cumulative traveler idling time saved across all 12 intersections every year.

DAILY SAVING: 4,983 HOURS / DAY
ANNUAL FUEL SAVED
7.64L Litres

Petroleum fuel saved by eliminating uncoordinated red-light idling along the corridor.

APPROX: 763,894 LITRES TOTAL
ECONOMIC TIME VALUE
₹21.83 Cr

Monetized annual urban productivity benefit based on conservative travel-time savings valuation.

ESTIMATED INFRASTRUCTURE PAYBACK: < 4 MONTHS

Comparative Analysis: DCI Sovereign Edge vs Industry Standards

Procurement evaluation criteria for Indian smart city municipal commissioners and EPC bidders.

EVALUATION METRICDATA CORE INFOTECH (EDGE AI)LEGACY PRE-TIMED (PRE-1990)FRAGILE CLOUD ITMS
Actuation Latency< 14.2 ms (Local Edge NPU)Static 60-120s intervals800ms - 3500ms (Cloud roundtrip)
Backhaul Failure BehaviorZero Impact (100% Autonomous)Continues fixed timersFreezes / Fails to default
Indian Mixed Traffic CalibrationVolumetric PCU (2W Swarms / Autos)None (Blind mechanical timer)Assumes Western lane lines
Failsafe ProtectionHardwired Relay Interlock (<80ms)Electro-mechanical cam switchSoftware exception catch
Ongoing Cloud FeesZero (Permanent Sovereign License)ZeroRecurring annual cloud bills
READY TO INTEGRATE DCI ITMS MODULES INTO YOUR TENDER / CORRIDOR?
We supply EPC bidders and municipal corporations with comprehensive technical schedules and Bill of Materials (BOM).
REQUEST BILL OF MATERIALS (BOM) →